Toyota 4ranner + 1. Maintenance instruction + 2. Maintenance + 3. Engines - 4. Systems of heating, ventilation 4.1. Specifications 4.2. Antifreeze 4.3. Thermostat 4.4. Krylchatka of the fan and hydrocoupling 4.5. Radiator and tank 4.6. Oil cooler + 4.7. Pump 4.8. Liquid temperature sensor 4.9. Electric motor and chain of the fan of a heater 4.10. Heater radiator 4.11. Control panel conditioning block + 4.12. Central air 4.13. Compressor + 5. Fuel and exhaust systems + 6. Transmissions + 7. Transmission elements + 8. Brake system + 9. Suspension bracket and steering + 10. Body + 11. Electric equipment + 12. Electroschemes
|
Standard arrangement of cables of control of the conditioning block
1. Airinflow gate cable 2. Cable of the mixing gate
|
3. Cable of management of a ventilation stream |
Removal
PERFORMANCE ORDER |
1. Disconnect the battery from weight. |
2. Remove facing of the central panel (see subsection 10.23). |
|
3. Remove handles. |
4. Unscrew control panel screws. |
5. Give the panel on yourself, turn tags and disconnect cables, disconnect sockets. |
|
Installation
PERFORMANCE ORDER |
1. Assembly is carried out upside-down. |
2. Adjust cables. |
3. Check work of a heater. |
|
Adjustment
Adjustment of the gate of airinflow
|
1. Clip
2. The situation FRESH it (is completely open)
3. The situation RECIRC it (is completely closed) |
Adjustment of a cable of the mixing gate
|
1. Clip
2. Situation COOL/situation WARM |
Adjustment of a cable of the mode of heating
|
1. Clip
2. The situation FACE (on the person)
3. Situation DEF |
PERFORMANCE ORDER |
1. Transfer handles of management to the provisions RECIRC, COOL, DEF. |
2. For adjustment of a cable of the gate of airinflow transfer the lever to the situation FRESH, attach a cable and tighten a clip (see rice. Adjustment of the gate of airinflow). |
3. For adjustment of a cable of control of the mixing gate transfer the lever to the situation COOL, attach a cable and tighten a clip, pressing a cable cover (see rice. Adjustment of a cable of the mixing gate). |
4. For adjustment of a cable of the mode of heating transfer the lever to the situation DEF (defrosting), attach a cable and tighten a clip (see rice. Adjustment of a cable of the mode of heating). |
|
Check of a chain
Scheme of electric equipment of conditioning of salon
1. Electromagnetic coupling 2. Processor control unit 3. Ignition switch 4. Relay of back lamps 5. Switch of back lamps 6. Fan switch 7. Conditioner switch 8. Rheostat |
9. Heater safety lock 10. Electric motor 11. The electronic module (on cars with and/t) 12. Relay of pressure and thermoswitch 13. Main relay of a heater 14. Pulse block of ignition 15. Amplifier |
Table of check of the switch of a back heater
Position of the switch
|
The checked conclusions
|
Indication of a tester
|
OFF |
|
Chains are not present
|
LO |
2 – 3
|
The chain is
|
HI |
1 – 2 – 3
|
Chains are not present
|
PERFORMANCE ORDER |
1. Check the conditioner switch according to the scheme. |
|
2. Check the heater switch. If results of tests unsatisfactory, the control panel replace. |
|
|
|